Moving-Coil Panel Meters Ex Stock - MA16, MA17, MA19, MA12
Moving-coil Panel Meters
ext Stock MA16, MA17, MA19 and MA12 types are designed to measure d.c. voltage or d.c. current and other physical quantities converted into a current or voltage standard signal. Meters with built-in rectifiers can be used to measure a.c. voltage or a.c. current. exchangeable scales, for requirement meters can be made with additional setting pointer and/or the scale back lighting.
direct measuring ranges:
I = 40µA...25A,
U = 60mV...1000V,
Measuring ranges with external shunts: I = 1A...15kA, (see our offer)
Accuracy class: 1.5,
IP65:EA16, EA17, EA19, MA16, MA17, MA19, MA17P, MA19P, CA37, CA39, FA39, PA39.
Meters in IP65 casings available with dimensions: 48 x 48 mm, 72 x 72 mm, 96 x 96 mm
External dimensions:
48 x 48 x 58mm (MA16 type), 72 x 72 x 65mm (MA17, MA17P type), 96 x 96 x 65mm (MA19, MA19P type), 144 x 144 x 68mm (MA12 type)
EX STOCK-Moving Coil Panel Meter
MA16/50/O/0...50A/60MV/IP50 (MA16N AB1300000A8) 48X48 / 50A dc / 60mV
MA16/40VDC/O/0...40VDC/IP50 (MA16N A60900000A8) 48X48 / 40V dc
|
|
Data Sheet
|
Moving-iron meters - EA16, EA17, EA19, EA12
Moving-iron meters EA16, EA17, EA19 and EA12 types are destined to measure a.c. voltage or a.c. current. They measure the true RMS value of a.c. voltage or a.c. current.Meters can be made with additional setting pointer and/or the scale underlighting. IP65 protection grade in offered analog meter series EA16, EA17, EA19, MA16, MA17, MA19, MA17P, MA19P, CA37, CA39, FA39, PA39. IP65 Specially designed frames with a sealing enable the application of meters in very rugged atmospheric conditions. Meters in IP65 casings are available in following overall dimensions: 48 x 48 mm, 72 x 72 mm, 96 x 96 mm.
direct measuring ranges:
I = 100mA...100A
U = 6V...1kV
measuring ranges with external transformer:
I = 1A...10 kA
U = 4 kV...250 kV
accuracy class: 1.5
exchangeable scales
External dimensions:
48 x 48 x 58 mm (EA16) 72 x 72 x 65 mm (EA17)96 x 96 x 65 mm (EA19)144 x 144 x 68 mm (EA12)
|
|
|
Data Sheet
|
|
Moving-iron meters EB16 - RMS value of a.c. voltage or a.c. current Indicator
EB16 moving-iron meters are designed to measure a.c. current or a.c. voltage. They measure the true RMS value of a.c. voltage or a.c. current.
Direct measuring ranges:
I = 100 mA...25A
U = 6V...600V
Measuring ranges with external transformers:
I = 1A...10kA
U = 4kV...250kV
Accuracy class: 1.5
Mounting:DIN rail.
Dimensions: 53 x 90 x 65mm
|
|
Data Sheet
|
Voltmeters equipped with a change-over switch - EP27 i EP29
Voltmeters equipped with a change-over switch EP27 and EP29 type are designed to measure phase-to-phase and line-to-line voltages in low voltage power networks. A switch installed on the left side of the dial enables the selection of the measured voltage. They are particularly useful for measurements in electrical machine safeguard systems.
Direct measuring ranges: U = to 500 V,
Measuring ranges with voltage transformers: U=100 V or 110V,
Panel mount dimensions: 72 x 72 x 65mm (EP27 type) 96 x 96 x 65mm (EP29 type)
|
|
Data Sheet
|
Bimetallic ammeters - BA27, BA39, BE27 and BE39
Maximum ammeters - BA and BE series are destined to measure the averaging RMS value of a a.c. current, in a 8 or 15 minutes’ period. An additional red pointer, displaced by the black pointer, shows the maximal current value which occurred from the last zeroing of the meter indication. The applied bimetal movement is especially useful when measuring the load in power line, of generators, electrical motors and others, where important momentary changes of load occur.
Options
- with bimetallic movement - BA series
- with bimetallic and moving-iron movement - BE series
Direct measuring range for BA series: I = 0...6A
Direct measuring range for BE series: I = 0...1/2A, 0...5/10A
Measuring range with current transformer: I = 1 A or 5 A
Accuracy class: bimetallic movement: 3
Accuracy class - moving-iron movement: 1.5
Panel mount dimensions:72 x 72 x 61.5mm (BA27 and BE27 types),96 x 96 x 61.5mm (BA39 and BE39 types)
|
|
Data Sheet
|
Moving-coil meters - MB16
Moving-coil meters MB16 type are designed to measure d.c. current or d.c. voltage and other physical quantities converted into a current or voltage standard signal.
Direct measuring ranges:
I = 40µA...25A
U = 60mV...1000V
Measuring ranges with external shunts: I = 1A...15kA
Accuracy class: 1,5
Destined to be mounted on the DIN rail
External dimensions: 53 x 90 x 65mm
|
|
Data Sheet
|
Power meters PA39 type are destined for measurements of the active and reactive power in 1 and 3 phase power network. Applications: for measuring the active power in single-phase networks, for measuring the active power in three-phase three-wire and four-wire power networks, with balanced or unbalanced loads, for measuring the reactive power in three-phase three-wire and four-wire power networks,with balanced or unbalanced loads, with zero on the left side of the scale, for measuring the unidirectional power flow, with zero in the middle of the scale for measuring the bidirectional power flow.
Input voltage: U = to 690V, also for operation with voltage transformer
Current input: I = 1A or 5A, also for operation with current transformer
Accuracy class: 1.5
Panel Mount: 48 x 48 mm
IP Rating:65
|
|
Data Sheet
|
Power factor meters - FA39 and FA32 type
Power factor meters FA32 and FA39 type are designed to measure the phase angle difference between the voltage and the current in 1-phase or 3-phase a.c. power networks. Application: Three-phase assymetrical loaded network
input voltage for system in 1 phase network: U = 100...500V
input voltage for system in 3 phase network symetrical load: U = 100...500V
input current: I = 1A or 5A, also to the conjunction with current transformer
measuring ranges:0.5 cap...1...0.5 ind, 0.8 cap...1...0.2 ind, 0.85 cap...1...0.85 ind, 0 ind...1
accuracy class: 1.5
Panel Mounted: 96 x 96 x 65mm (FA39 IP65),144 x 144 x 68mm (FA32 type) |
|
Data Sheet
|
Frequency meters - CA37, CA39 and CA32
Frequency meters CA32, CA37 and CA39 types are designed to measure voltage frequency in a.c. electrical power networks.
Input voltage: U = 60V...690V,
Accuracy class: 0.2 for measuring ranges: 48...52 Hz, 58...62 Hz, 140...160 Hz, 180...220 Hz, 380...420 Hz,
Accuracy class: 0.5 for measuring ranges:45...55 Hz, 45...65 Hz, 55...65 Hz, 360...440 Hz,
Panel Mount:72 x 72 x 65mm (CA37 IP65),96 x 96 x 65mm (CA39 IP65),144 x 144 x 68mm (CA32)
IP65 protection grade in offered analog meter series: EA16, EA17, EA19, MA16, MA17, MA19, MA17P, MA19P, CA37, CA39, FA39, PA39.
|
|
Data Sheet
|
Slim moving-coil meters - MA1 and MA2
Slim edgewise moving-coil meters MA1 and MA2 type are designed to measure d.c. current or d.c. voltage and other physical quantities converted into a current or voltage standard signal. Meters with built-in rectifiers can be used to measure a.c. voltage or a.c. current.
direct measuring ranges:I = 60µA...4A, U = 60mV...600V
measuring ranges with external shunts: I = 1A...15kA
accuracy class: 1,5
Panel Mount Dimensions:72 x 24 x 93mm (MA1 type),96 x 24 x 119mm (MA2 type)
|
|
Data Sheet
|
|
|