CTU1 CTU1-U2-U3-U4 Thermocouple Sensor J/K

Industrial thermocouples CTU1-CTU2-CTU3-CTU4

Industrial thermocouples CTU1-CTU2-CTU3-CTU4 temperature sensor consisting two dissimilar electrical conductors forming an electrical junction. Heating the junction causes the thermoelectric effect generating a temperature proportional voltage.

  • Measuring Range J: -40...750°C K: -40...1000°C / -40...1100°C
  • Load max 0.1 Mpa
  • Immersion length L=500, 700, 1000,1400, 2000 mm
  • Diameter of measuring insert: 6mm/8mm/15mm
  • Process connection UC1-22, UC2-22
  • Wetted parts Heat-resisting steel 1.4841(*).
  • Intrinsically Safe Temperature Sensor Ex I M1 Ex ia I Ma ,
  • Ex I M1 Ex ia I Ma , Ex II 1/2 G Ex ia IIC T6..T1 Ga/Gb, Ex II 1D Ex iaD 20 T75°C Da
  • Measuring Junction Isolated
  • Vibration 2g